Explore an elevated standard for data center efficiency, cost savings, and sustainability.
![](https://nautilusdt.com/wp-content/uploads/quote-icon.png)
![](https://nautilusdt.com/wp-content/uploads/Rob-Dunn-Headshot.jpg)
Rob Dunn
/
CEO of Start Campus
EcoCore
The Foundation for Next-Generation Data Centers
![](https://nautilusdt.com/wp-content/uploads/mep-breakout.png)
![](https://nautilusdt.com/wp-content/uploads/nautilus-image-placeholder.png)
Harness Sustainability
Nautilus’ zero-water technology redefines efficiency.
Scale with Ease
Hyperscale data center expansion possible with 2.5MW Blocks.
Speed Up Deployment
EcoCore units are 60% factory-made for speed and fewer onsite errors.
Cool with Precision
Optimize temperature control in high-density areas using tailored cooling strategies.
Cooling Distribution Unit – COOL2500
Four parallel CDU units, each capable of delivering up to 833kW of heat rejection, ensuring optimal temperature control for the data center. Nautilus’ zero-water cooling technology makes it possible.
Primary Electrical Unit – PWR-LV-2500
Provides a robust 1250 kW of 415V 3-phase power distribution, ensuring uninterrupted performance for critical systems.
Reserve Power Unit – RES-LV-1250
Offers 1250kW of reserve power, configured in N+1 redundancy for dependable, seamless operation.
Aisle – AISLE-HT
Designed to accommodate a customized IT cooling solution, ensuring the data center operates at its best efficiency.
Aisle – AISLE-CL (Accessory)
Optimizes space for data center needs because of its construction on an interstitial structure and accessory space in the MEP.
![](https://nautilusdt.com/wp-content/uploads/EcoCorebuild_image1.png)
![](https://nautilusdt.com/wp-content/uploads/EcoCorebuild_image1-1024x693.png)
![](https://nautilusdt.com/wp-content/uploads/EcoCorebuild_image2-1024x693.png)
![](https://nautilusdt.com/wp-content/uploads/EcoCorebuild_image3-1024x693.png)
![](https://nautilusdt.com/wp-content/uploads/EcoCorebuild_image4-1024x693.png)
![](https://nautilusdt.com/wp-content/uploads/EcoCorebuild_image5-1024x693.png)
![](https://nautilusdt.com/wp-content/uploads/EcoCorebuild_image6-1024x693.png)
Download the Full Product Data Sheet Now
Integrate EcoCore into Your Data Center
We invite you to think differently about how your data center’s infrastructure will function. There is a better way.
You have a site in mind
You need a data center site
Calculate your data center needs
Slide the scale to compare data center sizes
![](https://nautilusdt.com/wp-content/uploads/set4_7-Photo-scaled-e1710474071844-1024x977.jpg)
Enhance Your Existing Data Center Project
With EcoCore Cooling
Have you already started your data center process or selected a site? Curious to learn whether you can implement EcoCore infrastructure cooling system? We make it easy.
Fast-Forward Your Data Center Launch
Vetted Sites
MARSEILLE, FRANCE
- Water quality assessment study
- Lease
- Regulatory and permitting matrix with estimated cost and schedule
- Critical IT load
- Data center size
- Power and fiber availability & connection studies resulting in contingent agreements
- Conceptual site layout
MILLINOCKET, ME, USA
100+MW Critical Load Capacity
1.15 PUE Guaranteed
- Water quality assessment study
- Lease
- Regulatory and permitting matrix with estimated cost and schedule
- Critical IT load
- Data center size
- Power and fiber availability & connection studies resulting in contingent agreements
- Conceptual site layout
LIMERICK, IRELAND
7.5MW Critical Load Capacity
1.15 PUE Guaranteed
- Water quality assessment study
- Lease
- Regulatory and permitting matrix with estimated cost and schedule
- Critical IT load
- Data center size
- Power and fiber availability & connection studies resulting in contingent agreements
- Conceptual site layout